| Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
http://tede.ucpel.edu.br:8080/jspui/handle/tede/275Registro completo de metadados
| Campo DC | Valor | Idioma |
|---|---|---|
| dc.creator | Silva Júnior, Neivo da | pt_BR |
| dc.creator.Lattes | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4138108H9&dataRevisao=null | por |
| dc.contributor.advisor1 | Lima, Maurício Silva de | pt_BR |
| dc.contributor.advisor1Lattes | http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4794134J4&dataRevisao=null | por |
| dc.date.accessioned | 2016-03-22T17:26:57Z | - |
| dc.date.available | 2006-06-14 | pt_BR |
| dc.date.issued | 2005-02-14 | pt_BR |
| dc.identifier.citation | SILVA JÚNIOR, Neivo da. Utilização do gama probe na detecção do linfonodo sentinela em pacientes com câncer de próstata. 2005. 28 f. Dissertação (Mestrado em saúde) - Universidade Catolica de Pelotas, Pelotas, 2005. | por |
| dc.identifier.uri | http://tede.ucpel.edu.br:8080/jspui/handle/tede/275 | - |
| dc.description.resumo | n | por |
| dc.description.abstract | Objective: The objective of this study is to describe the reproducibility of the sentinel lymph node technique in patients with prostate cancer and verify if there is improved accuracy over modified lymphadenectomy. Material and methods: Twenty-three patients with biopsy proven prostate cancer were enrolled in this study. Lymphoscintigraphy was performed after the transrectal administration of 99mTc-Sulphur Colloid guided by ultrasound, with one injection in each prostate lobe. Images were obtained 15 and 180 minutes after injection. Sentinel lymph node was harvested during surgery using a gamma probe, followed by extended lymphadenectomy. Results: The mean age of the patients in this study was 66 years old. An average of 3.36 sentinel lymph nodes was found for each patient. Radioactive lymph nodes were identified by the gamma probe in 21 out of 23 patients. In one of the patients there was no radiopharmaceutical migration from the injection site and in another the sentinel lymph node was visualized by lymphoscintigraphy but was not found during surgery. Three patients had lymph node metastasis; in one of these patients the sentinel lymph node was the only positive node and was found outside the modified lymphadenectomy region (dissection of the lymph nodes from the obturator fossa and the external iliac). Conclusion: Sentinel lymph node biopsy in prostate cancer adds important information to the staging of patients, not always attained through the lymphadenectomy restricted to the obturator fossa and external iliac. Such information is essencial for the choice of the best treatment to be applied. | eng |
| dc.description.provenance | Made available in DSpace on 2016-03-22T17:26:57Z (GMT). No. of bitstreams: 1 Neivo.pdf: 343535 bytes, checksum: e65c41380c8ceabe9bc780ffcc1c99f1 (MD5) Previous issue date: 2005-02-14 | eng |
| dc.format | application/pdf | por |
| dc.thumbnail.url | http://tede.ucpel.edu.br:8080/jspui/retrieve/1457/Neivo.pdf.jpg | * |
| dc.language | por | por |
| dc.publisher | Universidade Catolica de Pelotas | por |
| dc.publisher.department | saúde | por |
| dc.publisher.country | BR | por |
| dc.publisher.initials | Ucpel | por |
| dc.publisher.program | Mestrado em Saúde e Comportamento | por |
| dc.rights | Acesso Aberto | por |
| dc.subject | Ssentinel lymph node | por |
| dc.subject | lymphoscintigraphy | por |
| dc.subject | prostate cancer | por |
| dc.subject | gamma probe | por |
| dc.subject | Sentinel lymph node | eng |
| dc.subject | lymphoscintigraphy | eng |
| dc.subject | prostate cancer | eng |
| dc.subject | gamma probe | eng |
| dc.subject.cnpq | CNPQ::CIENCIAS DA SAUDE::MEDICINA | por |
| dc.title | Utilização do gama probe na detecção do linfonodo sentinela em pacientes com câncer de próstata | por |
| dc.type | Dissertação | por |
| Aparece nas coleções: | Biblioteca Digital de Teses e Dissertações | |
Arquivos associados a este item:
| Arquivo | Descrição | Tamanho | Formato | |
|---|---|---|---|---|
| Neivo.pdf | 335,48 kB | Adobe PDF | ![]() Baixar/Abrir Pré-Visualizar |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.

